TiF-DP. Femtosecond Ti:Sapphire Laser with Direct Diode Pumping
TiF-DP-20 | TiF-DP-30 | TiF-DP-50 | TiF-DP-50-LW5) | ||
Spectrally-limited pulse duration1) | <20 fs 1.2) | <30 fs 1.2) | <80 fs1) | <50 fs @ 900 nm | |
Spectrum width (FWHM)1) | >60 nm | >30 nm1) | >18 nm1) | >30 nm | |
Tuning range | 800±10 nm (fixed) | 770-830 nm | 760-840 nm | 850-970 nm | |
Average output power1), 3) | V5* | >175 mW1) | >200 mW1) | >250 mW1) | - |
V8* | >300 mW1) | >400 mW1) | >500 mW1) (up to 1 W upon request) |
>150 mW @ 920 nm |
General optical specifications | |
Pulse repetition rate (fixed) | 90±10 MHz |
Pump source | integrated, direct diode pump |
Spatial mode and М2 | ТЕМ00 (М2<1.2) |
Beam diameter (1/e2) | <2 mm |
Output polarization | linear, horizontal, PER >20 dB |
Beam divergence | <1 mrad |
Long-term stability3) | <0.5% rms |
Noise | <0.5% rms (10 Hz to 10 MHz bandwidth) |
Physical dimensions (L × W × H) | |
Laser head dimensions | 525 × 255 × 112 mm |
Laser control unit dimensions | 170 × 182 × 35 mm |
Closed-loop chiller dimensions | 248 × 345 × 215 mm |
Tubes and cables lenght | 2 m |
Environmental and utility specifications | |
Operating temperature | 15-30°С |
Relative humidity | <60%, non-condensing |
Voltage | single-phase; 100-240 VAC; 50/60 Hz |
Power consumption | <2 kW |
Available configuration packages4) | |
"Basic" package (default) | - thermally stabilized body - SMA pulse train sync output - humidity and temperature indicators inside the laser - mode-lock status LED indication - laser on/off, femtosecond mode start via software - pump diode currents controlvia software - USB 2.0 wavelength and spectum width tuning by stepper motors via software (wavelength calibration is not available. An external spectrometer to visualize the central wavelength and spectrum width is not included) PC requirements: USB 2.0 port, Windows 10 |
"Auto" package | - thermally stabilized body - SMA pulse train sync output - mode-lock status LED indication - built-in spectrometer - single-touch wavelength tuning w. presets - built-in power meter - active output power stability locking - automatic mode-lock start and monitoring - Windows software with configurable widgets PC requirements: USB 2.0 port, Windows 10 |
1) - when tuned to 800 nm; pulse duration is measured by the AA-10DD-12PS (Avesta) interferometric autocorrelator; 2) - with an external dispersion compensator (not included; offered separately, see APC); 3) - after 30 min warm-up with cold start, during 12-hour continuous operation under equal room temperature conditions using recommended stabilized closed-loop chiller with proper capacity and active output power locking ("Auto" package); 4) - please select one of the packages for your system; certain features may be tailored or combined differently according to specific customer requirements; 5) - For operation in the long-wave range it is necessary to use the Avesta FRESH laser internal volume cleaning and drying system. The data in the table may differ from the actual ones. The exact parameters are specified while ordering and indicated in the product data sheet. * - V5 and V8 - pumping power 5 W and 8 W. |
The novel TiF-DP system is a Ti:Sapphire femtosecond laser oscillator having its active medium directly pumped by emission from a laser diode assembly. Such architecture leads to significant cost reduction while system still maintains the output beam quality, pulse duration and long-term output power stability of conventional DPSS-laser-pumped systems. Average output power reaches 200 mW and is sufficient enough to use the TiF-DP series systems as a seed laser source for amplifier systems with enough headroom, as well as implement it in numerous scientific research applications. The laser design features a rigid monolithic thermally stabilized body and ensures long-term output power stability drift below 0.5% rms.
The laser system may be factory-optimized for any of the three main output pulse duration choices: 20, 30 or 50 fs (with 100 fs by special request). The general rule is that accessible values of output power and tuning range width increase with values of output pulse duration.
- measurement of spectrum shape and FWHM data in the laser's software with real-time pulse duration tuning via PC (in certain models);
- measurement and real-time tuning of central output wavelength via PC;
- oscillator regime indicator (CW regime or pulsed regime with mode-locking) on a PC or with an LED on the laser's body;
- remote mode-lock start or automatic start via PC;
- stabilization of output average power of the laser system;
- analog sync electric output for pulse train monitoring and third-party equipment synchronization.
- oscillator regime indicator (CW regime or pulsed regime with mode-locking) with an LED on the laser's body;
- remote mode-lock start via external wired push-button;
- analog sync electric output for pulse train monitoring and third-party equipment synchronization.
Related products
Latest News
Ti:S oscillator with up to 3 W output power at 100 fs
We have ramped up the maximum available output power for the TiF-100 series to more than 3 Watts at 800 nm, 100 fs, 80 MHz. The tuning range has also been extended to 720-950 nm, while an optional modification that covers 850-1040 nm is also available. The system features a high-power low-noise integrated DPSS laser […]
TiF-100ST-F6 femtosecond Ti:S oscillator with Frep locking for multiphoton microscopy at CANDLE, Armenia
The TiF-100ST-F6 femtosecond Ti:S oscillator with a built-in pump laser, also equipped with the ALock PLL electronics unit for pulse repetition rate locking to an external RF source has been installed at the Synchrotron Research Institute’s CANDLE facility in Armenia. The setup has been developed and commercialized during the joint Russia-Armenia project supported by FASIE (Innovation […]